KM-ASSYH2-04
51
M7050
Front section-M7050-upper cover front positioning cylinder-extension (middle), extension is abnormal, please check sensor X56
Sensor abnormality
The solution for the error described is likely to check the sensor X56 as it is not functioning properly. The upper cover front positioning cylinder-extension (middle) extension is abnormal and is likely the cause of this error. In order
KM-ASSYH2-04
52
M7051
Front section-M7051-upper cover front positioning cylinder-retracted (middle), retraction is abnormal, please check sensor X57
Sensor abnormality
The solution for the error described as Front section-M7051-upper cover front positioning cylinder-retracted (middle), retraction abnormal, please check sensor X57 involves checking the sensor X57 for any
KM-ASSYH2-04
53
M7052
Front section - M7052 - push PCB cylinder - extension (middle), extension is abnormal, please check sensor X60
Sensor abnormality
The solution to the error "Front section - M7052 - push PCB cylinder - extension (middle), extension is abnormal, please check sensor X60" is to either replace or repair the faulty sensor or component X
KM-ASSYH2-04
55
M7054
Front section-M7054-tilt cylinder-rising (middle), abnormal extension, please check sensor X62
Sensor abnormality
The solution for Front section-M7054-tilt cylinder-rising (middle), abnormal extension, please check sensor X62 error is likely related to a problem with the control sensor X62. It is recommended
KM-ASSYH2-04
56
M7055
Front section - M7055 - tilting cylinder - lowering (middle), retraction is abnormal, please check sensor X63
Sensor abnormality
The solution for the error Front section - M7055 - tilting cylinder - lowering (middle), retraction is abnormal, please check sensor X63 can be to ensure that the sensor X63 is functioning properly,
KM-ASSYH2-04
57
M7056
Front section-M7056-upper cover side positioning cylinder (rear), abnormal extension, please check sensor X65
Sensor abnormality
The issue with the rear side positioning for the cylinder can be resolved by checking sensor X65, as this may be causing the abnormal extension. If it is indeed the sensor that is the cause, the solution would involve fixing it or
KM-ASSYH2-04
60
M7059
Front section-M7059-upper cover front positioning cylinder-retract (rear), retraction is abnormal, please check sensor X70
Sensor abnormality
The solution for the error with the description Front section-M7059-upper cover front positioning cylinder-retract (rear), retraction is abnormal, please check sensor X70 is to inspect the sensor X7
KM-ASSYH2-04
62
M7061
Front section-M7061-push PCB cylinder-retract (rear), retraction is abnormal, please check sensor X72
Sensor abnormality
The solution to this error is to check the sensor X72, as it may be malfunctioning and triggering the abnormal retraction. If the sensor is found to be faulty, it will need to be replaced with a new one
KM-ASSYH2-04
63
M7062
Front section-M7062-tilt cylinder-lift (rear), abnormal extension, please check sensor X73
Sensor abnormality
The solution for the abnormal front section-M7062-tilt cylinder-lift (rear) error with sensor X73 is likely related to a faulty or failed sensor that is required to monitor the cylinder
KM-ASSYH2-04
64
M7063
Front section - M7063 - tilting cylinder - lowering (rear), retraction is abnormal, please check sensor X74
Sensor abnormality
The solution for the error described as Front section - M7063 - tilting cylinder - lowering (rear), retraction is abnormal, please check sensor X74 is to inspect and ensure proper functioning of sensor X7
KM-ASSYH2-04
65
M7064
Front section - M7064 - front suction nozzle presses down the cylinder - liter, and the extension is abnormal, please check sensor X30
Sensor abnormality
The solution for the error "Front section - M7064 - front suction nozzle presses down the cylinder - liter" and the abnormal extension is to check sensor X30 for any malfunctions or obstructions.
KM-ASSYH2-04
66
M7065
Front section-M7065-front suction nozzle downward pressure cylinder-lowering, retraction abnormality, please check sensor X31
Sensor abnormality
The solution to this error is to first check sensor X31, and if it shows an abnormality, it could be caused by a problem with the front suction nozzle or the downward pressure cylinder. The cylinder may
KM-ASSYH2-04
67
M7066
Front section-M7066-middle suction nozzle presses down the cylinder-liter, the extension is abnormal, please check the sensor X32
Sensor abnormality
The solution for the described error is to check if the sensor X32 is functioning correctly. If the issue persists, then the front section-middle suction nozzle may be damaged and needs to be repaired or replaced.
KM-ASSYH2-04
68
M7067
Front section-M7067-middle suction nozzle downward pressure cylinder-lowering, retraction abnormality, please check sensor X33
Sensor abnormality
The described error refers to a malfunction in the suction nozzle of the lowering and retraction cylinder in the front section of M7067. It is suggested to verify the sensor X33 for any abnormal read
KM-ASSYH2-04
69
M7068
Front section-M7068-rear suction nozzle presses down the cylinder-liter, and the extension is abnormal, please check sensor X34
Sensor abnormality
The solution for the error described as Front section-M7068-rear suction nozzle presses down the cylinder-liter, and the extension is abnormal, please check sensor X34 is to investigate if there
KM-ASSYH2-04
171
M7010
Later section-M7010 please confirm the status of the work area
Abnormal personnel operation
To diagnose the solution for the "Later section-M7010 please confirm the status of the work area" error, more specific details about the error and its associated work area are needed. Confirming the status of the work
KM-ASSYH2-04
173
M7012
Rear section-M7012-CCD compensation host computer has no response
Visual abnormality
The solution for the error "Rear section-M7012-CCD compensation host computer has no response" typically involves checking the connections between the rear section, the CCD (charge-coupled device), and the host computer to
KM-ASSYH2-04
174
M7013
Backend-M7013-Detection process host computer does not respond
Visual abnormality
The solution for the "Backend-M7013-Detection process host computer does not respond" error typically involves restarting the host computer, checking for any updates or patches, and ensuring that the required software is properly installed and configured.
KM-ASSYH2-04
175
M7014
Rear section-M7014-no response from scanning QR code host computer
Visual abnormality
The solution for the described error could be to check the network or computer connection, ensure the QR code scanner app is up to date, and check the QR code host computer's settings to comply with the requirements for scanning.
KM-ASSYH2-04
177
M7016
M7016-EMO&&DOOR is open, please check the safety door or emergency stop
Abnormal personnel operation
The M7016-EMO&&DOOR is open error signifies that the safety door or emergency stop is open, which is unsafe. The solution is to ensure that the safety door and emergency stop are properly closed before resuming work
KM-ASSYH2-04
178
M7017
M7017-Equipment model setting is abnormal, please set the model
Abnormal personnel operation
The solution for the M7017-Equipment model setting is abnormal error is to check for invalid or missing values in the model settings, and to update the model accordingly. Additionally, ensure that the equipment model being used is a
KM-ASSYH2-04
179
M7018
M7018-Please press the reset button before starting the automatic process
Abnormal personnel operation
M7018 error usually occurs when the printer's automatic process fails to initiate properly. The solution is to press the reset button or perform a power cycle to restart the printer.
KM-ASSYH2-04
180
M7019
M7019-The device has not returned to the origin, please execute the device to return to the origin first
Abnormal personnel operation
The solution to the M7019 error is to first execute the device to return to its origin before attempting any further actions. This error occurs when a device is not properly synchronized with its origin, and it requires the device to be returned to
KM-ASSYH2-04
181
M7020
Back section-M7020-Equipment reset abnormality
Electronic control abnormality
The recommended solution for the Back section-M7020-Equipment reset abnormality error is to check the communication between the components and reboot the device or equipment. If the issue persists, it may be necessary to contact
KM-ASSYH2-04
182
M7021
Communication abnormality between backend-M7021-PLC
Electronic control abnormality
The solution for a communication abnormality between backend-M7021-PLC and other devices may involve checking for hardware or software issues, ensuring proper wiring and connections, updating device drivers and firmware, or troubleshooting
KM-ASSYH2-04
183
M7022
Rear segment-M7022-Communication abnormality between front segment and rear segment
Electronic control abnormality
The solution for the Rear segment-M7022-Communication abnormality error between the front segment and rear segment typically involves correcting the communication protocol or reinitializing the rear segment. It may also involve updating the firm
KM-ASSYH2-04
184
M7023
Rear section-M7023-width-adjustable conveyor belt is not reset
Abnormal personnel operation
The solution to the error "Rear section-M7023-width-adjustable conveyor belt is not reset" involves disconnecting the conveyor belt and using a manual override to reset the tension system, then reconnecting
KM-ASSYH2-04
185
M7024
Rear section-M7024-The conveyor belt product cannot return to the origin
Abnormal personnel operation
This error occurs when a conveyor belt product is removed from its conveyor belt and cannot be returned to its original location. The solution may involve resetting the belt, verifying that the product is properly aligned, or contacting the manufacturer for assistance
KM-ASSYH2-04
186
M7025
Rear section-M7025-there is material in the waste discharge area
Abnormal personnel operation
To address the error "Rear section-M7025-There is material in the waste discharge area," it is important to locate the source of the material, clean the area thoroughly, and ensure that there is proper ventilation in
KM-ASSYH2-04
187
M7026
Rear section-M7026-return to origin or XY movement downward pressure cylinder is not above
Electronic control abnormality
The solution for the error "Rear section-M7026-return to origin or XY movement downward pressure cylinder is not above" typically involves adjusting the position of the rear section or pressure cylinder to ensure that it
KM-ASSYH2-04
188
M7027
Back section-M7027-start secondary positioning platform has materials, please take it out
Abnormal personnel operation
The error message "Back section-M7027-start secondary positioning platform has materials, please take it out?" indicates that there is a problem with a specific object or device related to the secondary positioning platform in a manufacturing process.
KM-ASSYH2-04
189
M7028
Post-M7028-Buffer area Tray is lost, please restart
Abnormal personnel operation
To resolve the error "Post-M7028-Buffer area Tray is lost, please restart," you should restart the buffer. You can do this by following these steps: 1) Stop the M7028 chip.
KM-ASSYH2-04
193
M7032
Rear section-M7032-Front buffer conveyor belt feeding operation timeout, please check sensor X23
Sensor abnormality
The solution for the error described as Rear section-M7032-Front buffer conveyor belt feeding operation timeout, please check sensor X23 involves either troubleshooting the sensor or replacing the conveyor belt. The specific solution
KM-ASSYH2-04
194
M7033
Rear section-M7033-the discharging operation of the front buffer conveyor belt has timed out, please check sensor X23
Sensor abnormality
The solution for the error described is to check sensor X23 to determine if it is malfunctioning, preventing the discharging operation of the front buffer conveyor belt from completing.
KM-ASSYH2-04
195
M7034
Rear section-M7034-Work area conveyor belt feeding operation timeout, please check sensor X24
Sensor abnormality
The solution for the error "Rear section-M7034-Work area conveyor belt feeding operation timeout, please check sensor X24" is to check the sensor X24 and verify whether it is working properly or needs to
KM-ASSYH2-04
196
M7035
Rear section-M7035-The discharging operation of the conveyor belt in the work area has timed out, please check sensor X24
Sensor abnormality
The solution for the error "Rear section-M7035-The discharging operation of the conveyor belt in the work area has timed out, please check sensor X24" is to ensure that the motor for the
KM-ASSYH2-04
197
M7036
Rear section-M7036-Work area blocking cylinder is rising abnormally, please check sensor X36
Sensor abnormality
The solution for the error described as Rear section-M7036-Work area blocking cylinder is rising abnormally, please check sensor X36 is to ensure that the sensor is functioning properly and the work area is clear of
KM-ASSYH2-04
198
M7037
Rear section-M7037-Work area blocking cylinder is abnormally descending, please check sensor X37
Sensor abnormality
This error message can occur when a sensor in the rear section of a machine is malfunctioning. The sensor is likely responsible for blocking the abnormal descending of the work area in the rear. The fix involves fixing or replacing the sensor.
KM-ASSYH2-04
199
M7038
Rear section-M7038-the working area side positioning cylinder extends abnormally, please check sensor X40
Sensor abnormality
The solution for the error described as Rear section-M7038-the working area side positioning cylinder extends abnormally, please check sensor X40 is to check the sensor X40 for any malfunction or damage
KM-ASSYH2-04
200
M7039
Rear section-M7039-The working area side positioning cylinder retracts abnormally, please check sensor X41
Sensor abnormality
The solution for the error described as Rear section-M7039-The working area side positioning cylinder retracts abnormally, please check sensor X41 is to inspect and replace the sensor X41 if it
KM-ASSYH2-04
201
M7040
Rear section-M7040-upper cover side positioning cylinder (front), abnormal extension, please check sensor X43
Sensor abnormality
The solution for the error described as Rear section-M7040-upper cover side positioning cylinder (front), abnormal extension, please check sensor X43 is to check and replace the faulty sensor X43 as
KM-ASSYH2-04
202
M7041
Rear section-M7041-upper cover side positioning cylinder (front), retraction abnormality, please check sensor X44
Sensor abnormality
The solution to the Rear section-M7041-upper cover side positioning cylinder (front), retraction abnormality with sensor X44 is most likely a mechanical issue with the cylinder or a problem with the sensor
KM-ASSYH2-04
203
M7042
Rear section-M7042-upper cover front positioning cylinder-extension (front), extension is abnormal, please check sensor X45
Sensor abnormality
The solution to the errors "Rear section-M7042-upper cover front positioning cylinder-extension (front), extension is abnormal, please check sensor X45" is to inspect and replace the faulty sensor X
KM-ASSYH2-04
205
M7044
Rear section-M7044-push PCB cylinder-extension (front), extension is abnormal, please check sensor X47
Sensor abnormality
The error message "Rear section-M7044-push PCB cylinder-extension (front), extension is abnormal, please check sensor X47" indicates an issue with the extension of the PCB cylinder in the
KM-ASSYH2-04
207
M7046
Rear section-M7046-tilt cylinder-lift (front), abnormal extension, please check sensor X51
Sensor abnormality
The solution for the error Rear section-M7046-tilt cylinder-lift (front), abnormal extension, please check sensor X51 is to replace or repair the defective sensor X51. The problem
KM-ASSYH2-04
209
M7048
Rear section-M7048-upper cover side positioning cylinder (middle), abnormal extension, please check sensor X54
Sensor abnormality
To resolve the error with the abnormal extension of the rear section M7048-upper cover side positioning cylinder (middle) sensor X54, follow these steps: 1. Check the sensor X54
KM-ASSYH2-04
210
M7049
Rear section-M7049-upper cover side positioning cylinder (middle), retraction abnormality, please check sensor X55
Sensor abnormality
The solution for the Rear section-M7049-upper cover side positioning cylinder (middle) retraction abnormality error described as "please check sensor X55" is to locate the sensor and verify if it
KM-ASSYH2-04
212
M7051
Rear section-M7051-upper cover front positioning cylinder-retracted (middle), retraction is abnormal, please check sensor X57
Sensor abnormality
The solution for the error "Rear section-M7051-upper cover front positioning cylinder-retracted (middle), retraction is abnormal, please check sensor X57" is to inspect and adjust sensor X
KM-ASSYH2-04
213
M7052
Rear section-M7052-push PCB cylinder-extension (middle), extension is abnormal, please check sensor X60
Sensor abnormality
The solution for this error is to first check the sensor X60 for any issue and if that cannot be resolved, then to remove the outer PCB cylinder and check the components inside. If there are any mechanical issues, it may be necessary
KM-ASSYH2-04
214
M7053
Rear section-M7053-push PCB cylinder-retract (middle), retraction is abnormal, please check sensor X61
Sensor abnormality
The error Rear section-M7053-push PCB cylinder-retract (middle), retraction is abnormal, please check sensor X61 indicates a problem with the sensor X61. Check the sensor for potential
KM-ASSYH2-04
216
M7055
Rear section - M7055 - tilting cylinder - lowering (middle), retraction is abnormal, please check sensor X63
Sensor abnormality
The solution to the error "Rear section - M7055 - tilting cylinder - lowering (middle), retraction is abnormal, please check sensor X63" is likely to involve checking and possibly replacing the failed sensor
KM-ASSYH2-04
217
M7056
Rear section-M7056-upper cover side positioning cylinder (rear), abnormal extension, please check sensor X65
Sensor abnormality
The solution to the error Rear section-M7056-upper cover side positioning cylinder (rear), abnormal extension, please check sensor X65, is to reset the sensor and check the connection for any issues.
KM-ASSYH2-04
218
M7057
Rear section-M7057-upper cover side positioning cylinder (rear), retraction abnormality, please check sensor X66
Sensor abnormality
The solution for the error is to check the sensor X66, which may be malfunctioning and causing the retraction abnormality with the rear section-M7057-upper cover side positioning cylinder (rear).
KM-ASSYH2-04
219
M7058
Rear section-M7058-upper cover front positioning cylinder-extension (rear), extension is abnormal, please check sensor X67
Sensor abnormality
The solution to the error "Rear section-M7058-upper cover front positioning cylinder-extension (rear), extension is abnormal, please check sensor X67" is to inspect and test Sensor X6
KM-ASSYH2-04
220
M7059
Rear section-M7059-upper cover front positioning cylinder-retract (rear), retraction is abnormal, please check sensor X70
Sensor abnormality
The solution for the error M7059-upper cover front positioning cylinder-retract (rear), retraction is abnormal, please check sensor X70 is to locate and repair the sensor X70. This may
KM-ASSYH2-04
221
M7060
Rear section-M7060-push PCB cylinder-extend (rear), the extension is abnormal, please check sensor X71
Sensor abnormality
The error message "Rear section-M7060-push PCB cylinder-extend (rear), the extension is abnormal, please check sensor X71" indicates that there is an issue with the rear of a computer
KM-ASSYH2-04
222
M7061
Rear section-M7061-push PCB cylinder-retract (rear), retraction is abnormal, please check sensor X72
Sensor abnormality
The solution for the error "Rear section-M7061-push PCB cylinder-retract (rear), retraction is abnormal, please check sensor X72" is to check sensor X72 for any
KM-ASSYH2-04
223
M7062
Rear section-M7062-tilt cylinder-lift (rear), abnormal extension, please check sensor X73
Sensor abnormality
Without sensor X73 properly functioning, the rear section-M7062-tilt cylinder-lift (rear) may have abnormal extension. This would need to be corrected for the vehicle to operate normally.
KM-ASSYH2-04
224
M7063
Rear section - M7063 - tilting cylinder - lowering (rear), retraction is abnormal, please check sensor X74
Sensor abnormality
To fix the error "Rear section - M7063 - tilting cylinder - lowering (rear), retraction is abnormal, please check sensor X74," you first need to identify the model of the vehicle.
KM-ASSYH2-04
225
M7064
Rear section - M7064 - front suction nozzle presses the cylinder - up, and the extension is abnormal, please check sensor X30
Sensor abnormality
The solution for the described error is to check the sensor X30. If the sensor reads out of bounds or is damaged, it can cause the rear section of the machine to press the cylinder abnormally, and the front suction no
KM-ASSYH2-04
226
M7065
Rear section-M7065-front suction nozzle downward pressure cylinder-lowering, retraction abnormality, please check sensor X31
Sensor abnormality
The solution to the error described as Rear section-M7065-front suction nozzle downward pressure cylinder-lowering, retraction abnormality, please check sensor X31 may involve troubleshooting
KM-ASSYH2-04
227
M7066
Rear section-M7066-middle suction nozzle presses down the cylinder-liter, the extension is abnormal, please check the sensor X32
Sensor abnormality
The problem with the M7066-middle suction nozzle pressing down the cylinder-liter and extending abnormally has been identified as a faulty sensor X32. The solution recommended is to replace the faulty sensor
KM-ASSYH2-04
228
M7067
Rear section-M7067-middle suction nozzle downward pressure cylinder-lowering, retraction abnormality, please check sensor X33
Sensor abnormality
The solution for the error described is to check sensor X33, which may be malfunctioning or not providing accurate readings. Checking the sensor will help to identify any issues and correct the abnormality associated with the middle suction no
KM-ASSYH2-04
59
M7058
Front section - M7058 - upper cover front positioning cylinder - extension (rear), extension is abnormal, please check sensor X67
Sensor abnormality
The solution for the M7058 error with upper cover front positioning cylinder abnormal extension is to inspect and reset the sensor X67. If the issue continues, the cylinder may require maintenance or replacement.
KM-ASSYH2-04
206
M7045
Rear section-M7045-push PCB cylinder-retract (front), retraction is abnormal, please check sensor X50
Sensor abnormality
The solution for the error Rear section-M7045-push PCB cylinder-retract (front), retraction is abnormal, please check sensor X50 is to check the sensor X50 for any faults
KM-ASSYH2-05
213
M7052
Rear section PLC2-M7052-the vacuum is abnormal when taking off the upper cover, please check whether the X57 vacuum is abnormal
Electronic control abnormality
The solution to the error of abnormal vacuum in the rear section PLC2-M7052 when taking off the upper cover is to check whether the X57 vacuum is abnormal.
KM-ASSYH2-05
214
M7053
The backend PLC2-M7053-Product No. 1 failed to scan the code, please check whether the barcode is abnormal
Visual abnormality
The solution to the PLC2-M7053-Product No. 1 failed to scan code error is to check if the barcode is readable or abnormal. In this case, it is important to verify that the bar
KM-ASSYH2-05
215
M7054
The backend PLC2-M7054-Product No. 2 failed to scan the code, please check whether the barcode is abnormal
Visual abnormality
The error message "PLC2-M7054 Product No. 2 failed to scan the code" usually means either the PLC or barcode scanner hardware is faulty, or the barcode is abnormal or incompatible
KM-ASSYH2-05
216
M7055
The backend PLC2-M7055-Product No. 3 failed to scan the code, please check whether the barcode is abnormal
Visual abnormality
The solution for the error described as "The backend PLC2-M7055-Product No. 3 failed to scan the code, please check whether the barcode is abnormal?" is to either verify that the barcode is
KM-ASSYH2-05
217
M7056
The backend PLC2-M7056-Product No. 4 failed to scan the code, please check whether the barcode is abnormal
Visual abnormality
There could be several possible reasons why the PLC2-M7056-Product No. 4 failed to scan the code. It is recommended to check if the barcode is damaged, dirty, or if there is any misalign
KM-ASSYH2-05
218
M7057
The backend PLC2-M7057-Product No. 5 failed to scan the code, please check whether the barcode is abnormal
Visual abnormality
The solution to the error "The backend PLC2-M7057-Product No. 5 failed to scan the code, please check whether the barcode is abnormal?" is to verify that the barcode is correctly printed and
KM-ASSYH2-05
219
M7058
The backend PLC2-M7058-Product No. 6 failed to scan the code, please check whether the barcode is abnormal
Visual abnormality
The solution for the error "The backend PLC2-M7058-Product No. 6 failed to scan the code, please check whether the barcode is abnormal" is to review the barcode for any errors or anom
KM-ASSYH2-05
220
M7059
Backend PLC2-M7059-camera photo recognition failed
Visual abnormality
The solution for the PLC2-M7059-camera photo recognition error could be to check if the camera is connected and has clear coverage of the area to be recognized. If the issue persists, software updates or hardware replacement may
KM-ASSYH2-05
221
M7060
Post-stage PLC2-M7060-Pressure value reading failed, please check
Electronic control abnormality
The solution for the error "Post-stage PLC2-M7060-Pressure value reading failed, please check?" may vary depending on the specific issue. However, some potential steps to troubleshoot the issue include resetting
KM-ASSYH2-05
225
M7064
Rear section PLC2-M7064-Extrusion abnormality of the front positioning cylinder in the pressing area-X74
Organizational Abnormality
The solution for the Rear section PLC2-M7064-Extrusion abnormality of the front positioning cylinder in the pressing area-X74 would involve identifying the root cause of the issue, making necessary
KM-ASSYH2-05
226
M7065
Rear section PLC2-M7065-retraction abnormality of the front positioning cylinder in the pressing area-X75
Organizational Abnormality
The Rear section PLC2-M7065 retraction abnormality of the front positioning cylinder in the pressing area X75 can be resolved by verifying the sensor wiring connections and ensuring that all equipment is functioning
KM-ASSYH2-05
227
M7066
Rear section PLC2-M7066-Extrusion abnormality of side positioning cylinder in pressing area-X72
Organizational Abnormality
The solution for the error described as Rear section PLC2-M7066-Extrusion abnormality of side positioning cylinder in pressing area-X72 is likely related to a malfunction in the positioning
KM-ASSYH2-05
228
M7067
Rear section PLC2-M7067-pressure area side positioning cylinder retraction abnormality-X73
Organizational Abnormality
The error Rear section PLC2-M7067-pressure area side positioning cylinder retraction abnormality-X73 may be due to issues with the PLC or the connecting hardware between the PLC and
KM-ASSYH2-05
229
M7068
Rear section PLC2-M7068-pressure area lower pressure cylinder 1 rises abnormally-X76
Organizational Abnormality
The solution to the Rear section PLC2-M7068-pressure area lower pressure cylinder 1 rises abnormally-X76 error typically involves adjusting the pressure settings on the affected cylinder to ensure
KM-ASSYH2-05
197
M7036
Rear section PLC2-M7036-the working area blocking cylinder is rising abnormally, please check sensor X52
Sensor abnormality
The solution for this error may involve checking the sensor X52 for any blockages or malfunctions that may be preventing the working area blocking cylinder from functioning properly. In some cases, it may also be necessary to adjust the cylinder settings to
KM-ASSYH2-05
198
M7037
Rear section PLC2-M7037-the working area blocking cylinder is abnormally descending, please check sensor X53
Sensor abnormality
To solve the error with the Rear section PLC2-M7037 and the abnormally descending working area blocking cylinder, the sensor X53 should be checked for any malfunctions or failures. The sensor provides information
KM-ASSYH2-05
199
M7038
Rear section PLC2-M7038-the working area side positioning cylinder extends abnormally, please check sensor X54
Sensor abnormality
The solution for the error described as "Rear section PLC2-M7038-the working area side positioning cylinder extends abnormally, please check sensor X54" may involve assessing the status of sensor X
KM-ASSYH2-05
200
M7039
Rear section PLC2-M7039-the working area side positioning cylinder retracts abnormally, please check the sensor X55
Sensor abnormality
The solution for the error with Rear section PLC2-M7039 and the abnormal retraction of the working area side positioning cylinder is to check and possibly replace sensor X55. This sensor controls the positioning
KM-ASSYH2-05
209
M7048
Rear section PLC2-M7048-the picking clamp is rising abnormally, please check the sensor-X60
Sensor abnormality
The solution for the error Rear section PLC2-M7048 may involve checking the sensor X60 for any unusual readings or malfunction, which may be causing the picking clamp to rise abnormally. Identify
KM-ASSYH2-05
210
M7049
Rear section PLC2-M7049-the picking clamp has dropped abnormally, please check the sensor-X61
Sensor abnormality
The solution to the error described as Rear section PLC2-M7049-the picking clamp has dropped abnormally, please check the sensor-X61 would be to investigate the sensor and ensure it is working correctly
KM-ASSYH2-05
211
M7050
Rear section PLC2-M7050-the discharge clamp claw rises abnormally, please check the sensor-X62
Sensor abnormality
The solution for the error described for Rear section PLC2-M7050 is to verify the connection of sensor-X62 and check its output for any unusual readings. The discharge clamp claw may be rising
KM-ASSYH2-05
212
M7051
Rear section PLC2-M7051-the discharge clamp is abnormally falling, please check the sensor-X63
Sensor abnormality
The solution for the error described as Rear section PLC2-M7051 is to check the discharge clamp sensor-X63 for an abnormality. If the sensor is found to be faulty, the cl
KM-ASSYH2-05
291
M7130
Rear section PLC2-M7130-Please remove the TRAY plate from the conveyor belt first
Abnormal personnel operation
One possible solution for this error is to physically remove the TRAY plate from the conveyor belt before the PLC2-M7130 can be accessed. This should prevent any interference or damage to the belt caused by the plate's
KM-ASSYH2-05
1
M7000
The front-end PLC1-M7000-starts to detect that there is material in the work area, please confirm the status of the work area
Abnormal personnel operation
Unfortunately, without any context or additional information provided, it's impossible to provide a specific solution to the described error. However, it is recommended to check the documentation and user manuals for the PLC1-M7000, as
KM-ASSYH2-05
17
M7016
If the front section PLC1-M7016-EMO&&DOOR is opened, please check the safety door or emergency stop X17
Abnormal personnel operation
The solution for this error is to check the safety door or emergency stop X17 when the front section PLC1-M7016-EMO&&DOOR is opened.
KM-ASSYH2-05
18
M7017
Front stage PLC1-M7017-Equipment model setting is abnormal, please set the model
Abnormal personnel operation
The solution for the abnormal Front stage PLC1-M7017 equipment model setting is to set a new, valid model in the PLC. This can usually be done through the PLC's programming software or by physically reset
KM-ASSYH2-05
19
M7018
Front stage PLC1-M7018-Please press the reset button before starting the automatic process
Abnormal personnel operation
The solution for the Front stage PLC1-M7018 error described as "Please press the reset button before starting the automatic process" is as follows: Press the reset button before starting the automatic process. This process should restart and run
KM-ASSYH2-05
20
M7019
Previous PLC1-M7019-The equipment has not returned to the origin, please perform the equipment return to the origin first
Abnormal personnel operation
The solution to the error "Previous PLC1-M7019-The equipment has not returned to the origin, please perform the equipment return to the origin first" is to first perform the equipment return to the origin before proceeding with
KM-ASSYH2-05
21
M7020
Front section PLC1-M7020-There is material in the pressing area, please take it away first
Abnormal personnel operation
The solution for the "Pressing Area Full Error" in PLC1-M7020 is to remove any accumulated material from the pressing area before attempting to continue operation. This can be accomplished by physically removing the material or activating
KM-ASSYH2-05
22
M7021
Front stage PLC1-M7021-the Z-axis is not in the safe position during reset, please perform return to origin first
Abnormal personnel operation
The solution to the error "Front stage PLC1-M7021-the Z-axis is not in the safe position during reset" is to perform a return to origin first, which will ensure that the axis is in its safe
KM-ASSYH2-05
23
M7022
Previous section PLC1-M7022-timed out 10S while waiting for the scan code result
Visual abnormality
The solution for the error is to check the PLC's settings and ensure that the scan code result communication timeout is set correctly. If it is not working, you may need to update the PLC's firmware or contact technical support for
KM-ASSYH2-05
24
M7023
Front section PLC1-M7023-waiting for the camera to take pictures timed out 10S
Visual abnormality
The error "Front section PLC1-M7023-waiting for the camera to take pictures timed out 10S" can be resolved by checking the camera settings and ensuring that it is properly connected to the PLC
KM-ASSYH2-05
25
M7024
Front section PLC1-M7024-waiting for the next camera to take pictures timed out 10S
Visual abnormality
The solution for the error described as the front section PLC1-M7024 waiting for the next camera to take pictures timed out 10S could involve checking the camera configuration, ensuring proper camera communication, adjusting camera settings
KM-ASSYH2-05
26
M7025
Front-end PLC1-M7025-timeout 10S waiting for the host computer to reply to the assembly point
Machine communication abnormality
The solution for Front-end PLC1-M7025-timeout 10S waiting for the host computer to reply to the assembly point is to ensure that the host computer's firmware version is compatible with PLC1
KM-ASSYH2-05
28
M7027
Front stage PLC1-M7027-waiting for the host computer to reply LINK result timed out 10S
Machine communication abnormality
The solution for the described error is to increase the timeout value in the Link Communication Manager settings, such as by increasing the "Reply Timeout" setting to a value of 10 seconds or higher. It's also recommended to check the