KM-ASSYH2-04
| 51
|
M7050
|
Front section-M7050-upper cover front positioning cylinder-extension (middle), extension is abnormal, please check sensor X56
|
Sensor abnormality
|
The solution for the error described is likely to check the sensor X56 as it is not functioning properly. The upper cover front positioning cylinder-extension (middle) extension is abnormal and is likely the cause of this error. In order
|
KM-ASSYH2-04
| 52
|
M7051
|
Front section-M7051-upper cover front positioning cylinder-retracted (middle), retraction is abnormal, please check sensor X57
|
Sensor abnormality
|
The solution for the error described as Front section-M7051-upper cover front positioning cylinder-retracted (middle), retraction abnormal, please check sensor X57 involves checking the sensor X57 for any
|
KM-ASSYH2-04
| 53
|
M7052
|
Front section - M7052 - push PCB cylinder - extension (middle), extension is abnormal, please check sensor X60
|
Sensor abnormality
|
The solution to the error "Front section - M7052 - push PCB cylinder - extension (middle), extension is abnormal, please check sensor X60" is to either replace or repair the faulty sensor or component X
|
KM-ASSYH2-04
| 55
|
M7054
|
Front section-M7054-tilt cylinder-rising (middle), abnormal extension, please check sensor X62
|
Sensor abnormality
|
The solution for Front section-M7054-tilt cylinder-rising (middle), abnormal extension, please check sensor X62 error is likely related to a problem with the control sensor X62. It is recommended
|
KM-ASSYH2-04
| 56
|
M7055
|
Front section - M7055 - tilting cylinder - lowering (middle), retraction is abnormal, please check sensor X63
|
Sensor abnormality
|
The solution for the error Front section - M7055 - tilting cylinder - lowering (middle), retraction is abnormal, please check sensor X63 can be to ensure that the sensor X63 is functioning properly,
|
KM-ASSYH2-04
| 57
|
M7056
|
Front section-M7056-upper cover side positioning cylinder (rear), abnormal extension, please check sensor X65
|
Sensor abnormality
|
The issue with the rear side positioning for the cylinder can be resolved by checking sensor X65, as this may be causing the abnormal extension. If it is indeed the sensor that is the cause, the solution would involve fixing it or
|
KM-ASSYH2-04
| 60
|
M7059
|
Front section-M7059-upper cover front positioning cylinder-retract (rear), retraction is abnormal, please check sensor X70
|
Sensor abnormality
|
The solution for the error with the description Front section-M7059-upper cover front positioning cylinder-retract (rear), retraction is abnormal, please check sensor X70 is to inspect the sensor X7
|
KM-ASSYH2-04
| 62
|
M7061
|
Front section-M7061-push PCB cylinder-retract (rear), retraction is abnormal, please check sensor X72
|
Sensor abnormality
|
The solution to this error is to check the sensor X72, as it may be malfunctioning and triggering the abnormal retraction. If the sensor is found to be faulty, it will need to be replaced with a new one
|
KM-ASSYH2-04
| 63
|
M7062
|
Front section-M7062-tilt cylinder-lift (rear), abnormal extension, please check sensor X73
|
Sensor abnormality
|
The solution for the abnormal front section-M7062-tilt cylinder-lift (rear) error with sensor X73 is likely related to a faulty or failed sensor that is required to monitor the cylinder
|
KM-ASSYH2-04
| 64
|
M7063
|
Front section - M7063 - tilting cylinder - lowering (rear), retraction is abnormal, please check sensor X74
|
Sensor abnormality
|
The solution for the error described as Front section - M7063 - tilting cylinder - lowering (rear), retraction is abnormal, please check sensor X74 is to inspect and ensure proper functioning of sensor X7
|
KM-ASSYH2-04
| 65
|
M7064
|
Front section - M7064 - front suction nozzle presses down the cylinder - liter, and the extension is abnormal, please check sensor X30
|
Sensor abnormality
|
The solution for the error "Front section - M7064 - front suction nozzle presses down the cylinder - liter" and the abnormal extension is to check sensor X30 for any malfunctions or obstructions.
|
KM-ASSYH2-04
| 66
|
M7065
|
Front section-M7065-front suction nozzle downward pressure cylinder-lowering, retraction abnormality, please check sensor X31
|
Sensor abnormality
|
The solution to this error is to first check sensor X31, and if it shows an abnormality, it could be caused by a problem with the front suction nozzle or the downward pressure cylinder. The cylinder may
|
KM-ASSYH2-04
| 67
|
M7066
|
Front section-M7066-middle suction nozzle presses down the cylinder-liter, the extension is abnormal, please check the sensor X32
|
Sensor abnormality
|
The solution for the described error is to check if the sensor X32 is functioning correctly. If the issue persists, then the front section-middle suction nozzle may be damaged and needs to be repaired or replaced.
|
KM-ASSYH2-04
| 68
|
M7067
|
Front section-M7067-middle suction nozzle downward pressure cylinder-lowering, retraction abnormality, please check sensor X33
|
Sensor abnormality
|
The described error refers to a malfunction in the suction nozzle of the lowering and retraction cylinder in the front section of M7067. It is suggested to verify the sensor X33 for any abnormal read
|
KM-ASSYH2-04
| 69
|
M7068
|
Front section-M7068-rear suction nozzle presses down the cylinder-liter, and the extension is abnormal, please check sensor X34
|
Sensor abnormality
|
The solution for the error described as Front section-M7068-rear suction nozzle presses down the cylinder-liter, and the extension is abnormal, please check sensor X34 is to investigate if there
|
KM-ASSYH2-04
| 171
|
M7010
|
Later section-M7010 please confirm the status of the work area
|
Abnormal personnel operation
|
To diagnose the solution for the "Later section-M7010 please confirm the status of the work area" error, more specific details about the error and its associated work area are needed. Confirming the status of the work
|
KM-ASSYH2-04
| 173
|
M7012
|
Rear section-M7012-CCD compensation host computer has no response
|
Visual abnormality
|
The solution for the error "Rear section-M7012-CCD compensation host computer has no response" typically involves checking the connections between the rear section, the CCD (charge-coupled device), and the host computer to
|
KM-ASSYH2-04
| 174
|
M7013
|
Backend-M7013-Detection process host computer does not respond
|
Visual abnormality
|
The solution for the "Backend-M7013-Detection process host computer does not respond" error typically involves restarting the host computer, checking for any updates or patches, and ensuring that the required software is properly installed and configured.
|
KM-ASSYH2-04
| 175
|
M7014
|
Rear section-M7014-no response from scanning QR code host computer
|
Visual abnormality
|
The solution for the described error could be to check the network or computer connection, ensure the QR code scanner app is up to date, and check the QR code host computer's settings to comply with the requirements for scanning.
|
KM-ASSYH2-04
| 177
|
M7016
|
M7016-EMO&&DOOR is open, please check the safety door or emergency stop
|
Abnormal personnel operation
|
The M7016-EMO&&DOOR is open error signifies that the safety door or emergency stop is open, which is unsafe. The solution is to ensure that the safety door and emergency stop are properly closed before resuming work
|
KM-ASSYH2-04
| 178
|
M7017
|
M7017-Equipment model setting is abnormal, please set the model
|
Abnormal personnel operation
|
The solution for the M7017-Equipment model setting is abnormal error is to check for invalid or missing values in the model settings, and to update the model accordingly. Additionally, ensure that the equipment model being used is a
|
KM-ASSYH2-04
| 179
|
M7018
|
M7018-Please press the reset button before starting the automatic process
|
Abnormal personnel operation
|
M7018 error usually occurs when the printer's automatic process fails to initiate properly. The solution is to press the reset button or perform a power cycle to restart the printer.
|
KM-ASSYH2-04
| 180
|
M7019
|
M7019-The device has not returned to the origin, please execute the device to return to the origin first
|
Abnormal personnel operation
|
The solution to the M7019 error is to first execute the device to return to its origin before attempting any further actions. This error occurs when a device is not properly synchronized with its origin, and it requires the device to be returned to
|
KM-ASSYH2-04
| 181
|
M7020
|
Back section-M7020-Equipment reset abnormality
|
Electronic control abnormality
|
The recommended solution for the Back section-M7020-Equipment reset abnormality error is to check the communication between the components and reboot the device or equipment. If the issue persists, it may be necessary to contact
|
KM-ASSYH2-04
| 182
|
M7021
|
Communication abnormality between backend-M7021-PLC
|
Electronic control abnormality
|
The solution for a communication abnormality between backend-M7021-PLC and other devices may involve checking for hardware or software issues, ensuring proper wiring and connections, updating device drivers and firmware, or troubleshooting
|
KM-ASSYH2-04
| 183
|
M7022
|
Rear segment-M7022-Communication abnormality between front segment and rear segment
|
Electronic control abnormality
|
The solution for the Rear segment-M7022-Communication abnormality error between the front segment and rear segment typically involves correcting the communication protocol or reinitializing the rear segment. It may also involve updating the firm
|
KM-ASSYH2-04
| 184
|
M7023
|
Rear section-M7023-width-adjustable conveyor belt is not reset
|
Abnormal personnel operation
|
The solution to the error "Rear section-M7023-width-adjustable conveyor belt is not reset" involves disconnecting the conveyor belt and using a manual override to reset the tension system, then reconnecting
|
KM-ASSYH2-04
| 185
|
M7024
|
Rear section-M7024-The conveyor belt product cannot return to the origin
|
Abnormal personnel operation
|
This error occurs when a conveyor belt product is removed from its conveyor belt and cannot be returned to its original location. The solution may involve resetting the belt, verifying that the product is properly aligned, or contacting the manufacturer for assistance
|
KM-ASSYH2-04
| 186
|
M7025
|
Rear section-M7025-there is material in the waste discharge area
|
Abnormal personnel operation
|
To address the error "Rear section-M7025-There is material in the waste discharge area," it is important to locate the source of the material, clean the area thoroughly, and ensure that there is proper ventilation in
|
KM-ASSYH2-04
| 187
|
M7026
|
Rear section-M7026-return to origin or XY movement downward pressure cylinder is not above
|
Electronic control abnormality
|
The solution for the error "Rear section-M7026-return to origin or XY movement downward pressure cylinder is not above" typically involves adjusting the position of the rear section or pressure cylinder to ensure that it
|
KM-ASSYH2-04
| 188
|
M7027
|
Back section-M7027-start secondary positioning platform has materials, please take it out
|
Abnormal personnel operation
|
The error message "Back section-M7027-start secondary positioning platform has materials, please take it out?" indicates that there is a problem with a specific object or device related to the secondary positioning platform in a manufacturing process.
|
KM-ASSYH2-04
| 189
|
M7028
|
Post-M7028-Buffer area Tray is lost, please restart
|
Abnormal personnel operation
|
To resolve the error "Post-M7028-Buffer area Tray is lost, please restart," you should restart the buffer. You can do this by following these steps: 1) Stop the M7028 chip.
|
KM-ASSYH2-04
| 193
|
M7032
|
Rear section-M7032-Front buffer conveyor belt feeding operation timeout, please check sensor X23
|
Sensor abnormality
|
The solution for the error described as Rear section-M7032-Front buffer conveyor belt feeding operation timeout, please check sensor X23 involves either troubleshooting the sensor or replacing the conveyor belt. The specific solution
|
KM-ASSYH2-04
| 194
|
M7033
|
Rear section-M7033-the discharging operation of the front buffer conveyor belt has timed out, please check sensor X23
|
Sensor abnormality
|
The solution for the error described is to check sensor X23 to determine if it is malfunctioning, preventing the discharging operation of the front buffer conveyor belt from completing.
|
KM-ASSYH2-04
| 195
|
M7034
|
Rear section-M7034-Work area conveyor belt feeding operation timeout, please check sensor X24
|
Sensor abnormality
|
The solution for the error "Rear section-M7034-Work area conveyor belt feeding operation timeout, please check sensor X24" is to check the sensor X24 and verify whether it is working properly or needs to
|
KM-ASSYH2-04
| 196
|
M7035
|
Rear section-M7035-The discharging operation of the conveyor belt in the work area has timed out, please check sensor X24
|
Sensor abnormality
|
The solution for the error "Rear section-M7035-The discharging operation of the conveyor belt in the work area has timed out, please check sensor X24" is to ensure that the motor for the
|
KM-ASSYH2-04
| 197
|
M7036
|
Rear section-M7036-Work area blocking cylinder is rising abnormally, please check sensor X36
|
Sensor abnormality
|
The solution for the error described as Rear section-M7036-Work area blocking cylinder is rising abnormally, please check sensor X36 is to ensure that the sensor is functioning properly and the work area is clear of
|
KM-ASSYH2-04
| 198
|
M7037
|
Rear section-M7037-Work area blocking cylinder is abnormally descending, please check sensor X37
|
Sensor abnormality
|
This error message can occur when a sensor in the rear section of a machine is malfunctioning. The sensor is likely responsible for blocking the abnormal descending of the work area in the rear. The fix involves fixing or replacing the sensor.
|
KM-ASSYH2-04
| 199
|
M7038
|
Rear section-M7038-the working area side positioning cylinder extends abnormally, please check sensor X40
|
Sensor abnormality
|
The solution for the error described as Rear section-M7038-the working area side positioning cylinder extends abnormally, please check sensor X40 is to check the sensor X40 for any malfunction or damage
|
KM-ASSYH2-04
| 200
|
M7039
|
Rear section-M7039-The working area side positioning cylinder retracts abnormally, please check sensor X41
|
Sensor abnormality
|
The solution for the error described as Rear section-M7039-The working area side positioning cylinder retracts abnormally, please check sensor X41 is to inspect and replace the sensor X41 if it
|
KM-ASSYH2-04
| 201
|
M7040
|
Rear section-M7040-upper cover side positioning cylinder (front), abnormal extension, please check sensor X43
|
Sensor abnormality
|
The solution for the error described as Rear section-M7040-upper cover side positioning cylinder (front), abnormal extension, please check sensor X43 is to check and replace the faulty sensor X43 as
|
KM-ASSYH2-04
| 202
|
M7041
|
Rear section-M7041-upper cover side positioning cylinder (front), retraction abnormality, please check sensor X44
|
Sensor abnormality
|
The solution to the Rear section-M7041-upper cover side positioning cylinder (front), retraction abnormality with sensor X44 is most likely a mechanical issue with the cylinder or a problem with the sensor
|
KM-ASSYH2-04
| 203
|
M7042
|
Rear section-M7042-upper cover front positioning cylinder-extension (front), extension is abnormal, please check sensor X45
|
Sensor abnormality
|
The solution to the errors "Rear section-M7042-upper cover front positioning cylinder-extension (front), extension is abnormal, please check sensor X45" is to inspect and replace the faulty sensor X
|
KM-ASSYH2-04
| 205
|
M7044
|
Rear section-M7044-push PCB cylinder-extension (front), extension is abnormal, please check sensor X47
|
Sensor abnormality
|
The error message "Rear section-M7044-push PCB cylinder-extension (front), extension is abnormal, please check sensor X47" indicates an issue with the extension of the PCB cylinder in the
|
KM-ASSYH2-04
| 207
|
M7046
|
Rear section-M7046-tilt cylinder-lift (front), abnormal extension, please check sensor X51
|
Sensor abnormality
|
The solution for the error Rear section-M7046-tilt cylinder-lift (front), abnormal extension, please check sensor X51 is to replace or repair the defective sensor X51. The problem
|
KM-ASSYH2-04
| 209
|
M7048
|
Rear section-M7048-upper cover side positioning cylinder (middle), abnormal extension, please check sensor X54
|
Sensor abnormality
|
To resolve the error with the abnormal extension of the rear section M7048-upper cover side positioning cylinder (middle) sensor X54, follow these steps:
1. Check the sensor X54
|
KM-ASSYH2-04
| 210
|
M7049
|
Rear section-M7049-upper cover side positioning cylinder (middle), retraction abnormality, please check sensor X55
|
Sensor abnormality
|
The solution for the Rear section-M7049-upper cover side positioning cylinder (middle) retraction abnormality error described as "please check sensor X55" is to locate the sensor and verify if it
|
KM-ASSYH2-04
| 212
|
M7051
|
Rear section-M7051-upper cover front positioning cylinder-retracted (middle), retraction is abnormal, please check sensor X57
|
Sensor abnormality
|
The solution for the error "Rear section-M7051-upper cover front positioning cylinder-retracted (middle), retraction is abnormal, please check sensor X57" is to inspect and adjust sensor X
|
KM-ASSYH2-04
| 213
|
M7052
|
Rear section-M7052-push PCB cylinder-extension (middle), extension is abnormal, please check sensor X60
|
Sensor abnormality
|
The solution for this error is to first check the sensor X60 for any issue and if that cannot be resolved, then to remove the outer PCB cylinder and check the components inside. If there are any mechanical issues, it may be necessary
|
KM-ASSYH2-04
| 214
|
M7053
|
Rear section-M7053-push PCB cylinder-retract (middle), retraction is abnormal, please check sensor X61
|
Sensor abnormality
|
The error Rear section-M7053-push PCB cylinder-retract (middle), retraction is abnormal, please check sensor X61 indicates a problem with the sensor X61. Check the sensor for potential
|
KM-ASSYH2-04
| 216
|
M7055
|
Rear section - M7055 - tilting cylinder - lowering (middle), retraction is abnormal, please check sensor X63
|
Sensor abnormality
|
The solution to the error "Rear section - M7055 - tilting cylinder - lowering (middle), retraction is abnormal, please check sensor X63" is likely to involve checking and possibly replacing the failed sensor
|
KM-ASSYH2-04
| 217
|
M7056
|
Rear section-M7056-upper cover side positioning cylinder (rear), abnormal extension, please check sensor X65
|
Sensor abnormality
|
The solution to the error Rear section-M7056-upper cover side positioning cylinder (rear), abnormal extension, please check sensor X65, is to reset the sensor and check the connection for any issues.
|
KM-ASSYH2-04
| 218
|
M7057
|
Rear section-M7057-upper cover side positioning cylinder (rear), retraction abnormality, please check sensor X66
|
Sensor abnormality
|
The solution for the error is to check the sensor X66, which may be malfunctioning and causing the retraction abnormality with the rear section-M7057-upper cover side positioning cylinder (rear).
|
KM-ASSYH2-04
| 219
|
M7058
|
Rear section-M7058-upper cover front positioning cylinder-extension (rear), extension is abnormal, please check sensor X67
|
Sensor abnormality
|
The solution to the error "Rear section-M7058-upper cover front positioning cylinder-extension (rear), extension is abnormal, please check sensor X67" is to inspect and test Sensor X6
|
KM-ASSYH2-04
| 220
|
M7059
|
Rear section-M7059-upper cover front positioning cylinder-retract (rear), retraction is abnormal, please check sensor X70
|
Sensor abnormality
|
The solution for the error M7059-upper cover front positioning cylinder-retract (rear), retraction is abnormal, please check sensor X70 is to locate and repair the sensor X70. This may
|
KM-ASSYH2-04
| 221
|
M7060
|
Rear section-M7060-push PCB cylinder-extend (rear), the extension is abnormal, please check sensor X71
|
Sensor abnormality
|
The error message "Rear section-M7060-push PCB cylinder-extend (rear), the extension is abnormal, please check sensor X71" indicates that there is an issue with the rear of a computer
|
KM-ASSYH2-04
| 222
|
M7061
|
Rear section-M7061-push PCB cylinder-retract (rear), retraction is abnormal, please check sensor X72
|
Sensor abnormality
|
The solution for the error "Rear section-M7061-push PCB cylinder-retract (rear), retraction is abnormal, please check sensor X72" is to check sensor X72 for any
|
KM-ASSYH2-04
| 223
|
M7062
|
Rear section-M7062-tilt cylinder-lift (rear), abnormal extension, please check sensor X73
|
Sensor abnormality
|
Without sensor X73 properly functioning, the rear section-M7062-tilt cylinder-lift (rear) may have abnormal extension. This would need to be corrected for the vehicle to operate normally.
|
KM-ASSYH2-04
| 224
|
M7063
|
Rear section - M7063 - tilting cylinder - lowering (rear), retraction is abnormal, please check sensor X74
|
Sensor abnormality
|
To fix the error "Rear section - M7063 - tilting cylinder - lowering (rear), retraction is abnormal, please check sensor X74," you first need to identify the model of the vehicle.
|
KM-ASSYH2-04
| 225
|
M7064
|
Rear section - M7064 - front suction nozzle presses the cylinder - up, and the extension is abnormal, please check sensor X30
|
Sensor abnormality
|
The solution for the described error is to check the sensor X30. If the sensor reads out of bounds or is damaged, it can cause the rear section of the machine to press the cylinder abnormally, and the front suction no
|
KM-ASSYH2-04
| 226
|
M7065
|
Rear section-M7065-front suction nozzle downward pressure cylinder-lowering, retraction abnormality, please check sensor X31
|
Sensor abnormality
|
The solution to the error described as Rear section-M7065-front suction nozzle downward pressure cylinder-lowering, retraction abnormality, please check sensor X31 may involve troubleshooting
|
KM-ASSYH2-04
| 227
|
M7066
|
Rear section-M7066-middle suction nozzle presses down the cylinder-liter, the extension is abnormal, please check the sensor X32
|
Sensor abnormality
|
The problem with the M7066-middle suction nozzle pressing down the cylinder-liter and extending abnormally has been identified as a faulty sensor X32. The solution recommended is to replace the faulty sensor
|
KM-ASSYH2-04
| 228
|
M7067
|
Rear section-M7067-middle suction nozzle downward pressure cylinder-lowering, retraction abnormality, please check sensor X33
|
Sensor abnormality
|
The solution for the error described is to check sensor X33, which may be malfunctioning or not providing accurate readings. Checking the sensor will help to identify any issues and correct the abnormality associated with the middle suction no
|
KM-ASSYH2-04
| 59
|
M7058
|
Front section - M7058 - upper cover front positioning cylinder - extension (rear), extension is abnormal, please check sensor X67
|
Sensor abnormality
|
The solution for the M7058 error with upper cover front positioning cylinder abnormal extension is to inspect and reset the sensor X67. If the issue continues, the cylinder may require maintenance or replacement.
|
KM-ASSYH2-04
| 206
|
M7045
|
Rear section-M7045-push PCB cylinder-retract (front), retraction is abnormal, please check sensor X50
|
Sensor abnormality
|
The solution for the error Rear section-M7045-push PCB cylinder-retract (front), retraction is abnormal, please check sensor X50 is to check the sensor X50 for any faults
|
KM-ASSYH2-05
| 213
|
M7052
|
Rear section PLC2-M7052-the vacuum is abnormal when taking off the upper cover, please check whether the X57 vacuum is abnormal
|
Electronic control abnormality
|
The solution to the error of abnormal vacuum in the rear section PLC2-M7052 when taking off the upper cover is to check whether the X57 vacuum is abnormal.
|
KM-ASSYH2-05
| 214
|
M7053
|
The backend PLC2-M7053-Product No. 1 failed to scan the code, please check whether the barcode is abnormal
|
Visual abnormality
|
The solution to the PLC2-M7053-Product No. 1 failed to scan code error is to check if the barcode is readable or abnormal. In this case, it is important to verify that the bar
|
KM-ASSYH2-05
| 215
|
M7054
|
The backend PLC2-M7054-Product No. 2 failed to scan the code, please check whether the barcode is abnormal
|
Visual abnormality
|
The error message "PLC2-M7054 Product No. 2 failed to scan the code" usually means either the PLC or barcode scanner hardware is faulty, or the barcode is abnormal or incompatible
|
KM-ASSYH2-05
| 216
|
M7055
|
The backend PLC2-M7055-Product No. 3 failed to scan the code, please check whether the barcode is abnormal
|
Visual abnormality
|
The solution for the error described as "The backend PLC2-M7055-Product No. 3 failed to scan the code, please check whether the barcode is abnormal?" is to either verify that the barcode is
|
KM-ASSYH2-05
| 217
|
M7056
|
The backend PLC2-M7056-Product No. 4 failed to scan the code, please check whether the barcode is abnormal
|
Visual abnormality
|
There could be several possible reasons why the PLC2-M7056-Product No. 4 failed to scan the code. It is recommended to check if the barcode is damaged, dirty, or if there is any misalign
|
KM-ASSYH2-05
| 218
|
M7057
|
The backend PLC2-M7057-Product No. 5 failed to scan the code, please check whether the barcode is abnormal
|
Visual abnormality
|
The solution to the error "The backend PLC2-M7057-Product No. 5 failed to scan the code, please check whether the barcode is abnormal?" is to verify that the barcode is correctly printed and
|
KM-ASSYH2-05
| 219
|
M7058
|
The backend PLC2-M7058-Product No. 6 failed to scan the code, please check whether the barcode is abnormal
|
Visual abnormality
|
The solution for the error "The backend PLC2-M7058-Product No. 6 failed to scan the code, please check whether the barcode is abnormal" is to review the barcode for any errors or anom
|
KM-ASSYH2-05
| 220
|
M7059
|
Backend PLC2-M7059-camera photo recognition failed
|
Visual abnormality
|
The solution for the PLC2-M7059-camera photo recognition error could be to check if the camera is connected and has clear coverage of the area to be recognized. If the issue persists, software updates or hardware replacement may
|
KM-ASSYH2-05
| 221
|
M7060
|
Post-stage PLC2-M7060-Pressure value reading failed, please check
|
Electronic control abnormality
|
The solution for the error "Post-stage PLC2-M7060-Pressure value reading failed, please check?" may vary depending on the specific issue. However, some potential steps to troubleshoot the issue include resetting
|
KM-ASSYH2-05
| 225
|
M7064
|
Rear section PLC2-M7064-Extrusion abnormality of the front positioning cylinder in the pressing area-X74
|
Organizational Abnormality
|
The solution for the Rear section PLC2-M7064-Extrusion abnormality of the front positioning cylinder in the pressing area-X74 would involve identifying the root cause of the issue, making necessary
|
KM-ASSYH2-05
| 226
|
M7065
|
Rear section PLC2-M7065-retraction abnormality of the front positioning cylinder in the pressing area-X75
|
Organizational Abnormality
|
The Rear section PLC2-M7065 retraction abnormality of the front positioning cylinder in the pressing area X75 can be resolved by verifying the sensor wiring connections and ensuring that all equipment is functioning
|
KM-ASSYH2-05
| 227
|
M7066
|
Rear section PLC2-M7066-Extrusion abnormality of side positioning cylinder in pressing area-X72
|
Organizational Abnormality
|
The solution for the error described as Rear section PLC2-M7066-Extrusion abnormality of side positioning cylinder in pressing area-X72 is likely related to a malfunction in the positioning
|
KM-ASSYH2-05
| 228
|
M7067
|
Rear section PLC2-M7067-pressure area side positioning cylinder retraction abnormality-X73
|
Organizational Abnormality
|
The error Rear section PLC2-M7067-pressure area side positioning cylinder retraction abnormality-X73 may be due to issues with the PLC or the connecting hardware between the PLC and
|
KM-ASSYH2-05
| 229
|
M7068
|
Rear section PLC2-M7068-pressure area lower pressure cylinder 1 rises abnormally-X76
|
Organizational Abnormality
|
The solution to the Rear section PLC2-M7068-pressure area lower pressure cylinder 1 rises abnormally-X76 error typically involves adjusting the pressure settings on the affected cylinder to ensure
|
KM-ASSYH2-05
| 197
|
M7036
|
Rear section PLC2-M7036-the working area blocking cylinder is rising abnormally, please check sensor X52
|
Sensor abnormality
|
The solution for this error may involve checking the sensor X52 for any blockages or malfunctions that may be preventing the working area blocking cylinder from functioning properly. In some cases, it may also be necessary to adjust the cylinder settings to
|
KM-ASSYH2-05
| 198
|
M7037
|
Rear section PLC2-M7037-the working area blocking cylinder is abnormally descending, please check sensor X53
|
Sensor abnormality
|
To solve the error with the Rear section PLC2-M7037 and the abnormally descending working area blocking cylinder, the sensor X53 should be checked for any malfunctions or failures. The sensor provides information
|
KM-ASSYH2-05
| 199
|
M7038
|
Rear section PLC2-M7038-the working area side positioning cylinder extends abnormally, please check sensor X54
|
Sensor abnormality
|
The solution for the error described as "Rear section PLC2-M7038-the working area side positioning cylinder extends abnormally, please check sensor X54" may involve assessing the status of sensor X
|
KM-ASSYH2-05
| 200
|
M7039
|
Rear section PLC2-M7039-the working area side positioning cylinder retracts abnormally, please check the sensor X55
|
Sensor abnormality
|
The solution for the error with Rear section PLC2-M7039 and the abnormal retraction of the working area side positioning cylinder is to check and possibly replace sensor X55. This sensor controls the positioning
|
KM-ASSYH2-05
| 209
|
M7048
|
Rear section PLC2-M7048-the picking clamp is rising abnormally, please check the sensor-X60
|
Sensor abnormality
|
The solution for the error Rear section PLC2-M7048 may involve checking the sensor X60 for any unusual readings or malfunction, which may be causing the picking clamp to rise abnormally. Identify
|
KM-ASSYH2-05
| 210
|
M7049
|
Rear section PLC2-M7049-the picking clamp has dropped abnormally, please check the sensor-X61
|
Sensor abnormality
|
The solution to the error described as Rear section PLC2-M7049-the picking clamp has dropped abnormally, please check the sensor-X61 would be to investigate the sensor and ensure it is working correctly
|
KM-ASSYH2-05
| 211
|
M7050
|
Rear section PLC2-M7050-the discharge clamp claw rises abnormally, please check the sensor-X62
|
Sensor abnormality
|
The solution for the error described for Rear section PLC2-M7050 is to verify the connection of sensor-X62 and check its output for any unusual readings. The discharge clamp claw may be rising
|
KM-ASSYH2-05
| 212
|
M7051
|
Rear section PLC2-M7051-the discharge clamp is abnormally falling, please check the sensor-X63
|
Sensor abnormality
|
The solution for the error described as Rear section PLC2-M7051 is to check the discharge clamp sensor-X63 for an abnormality. If the sensor is found to be faulty, the cl
|
KM-ASSYH2-05
| 291
|
M7130
|
Rear section PLC2-M7130-Please remove the TRAY plate from the conveyor belt first
|
Abnormal personnel operation
|
One possible solution for this error is to physically remove the TRAY plate from the conveyor belt before the PLC2-M7130 can be accessed. This should prevent any interference or damage to the belt caused by the plate's
|
KM-ASSYH2-05
| 1
|
M7000
|
The front-end PLC1-M7000-starts to detect that there is material in the work area, please confirm the status of the work area
|
Abnormal personnel operation
|
Unfortunately, without any context or additional information provided, it's impossible to provide a specific solution to the described error. However, it is recommended to check the documentation and user manuals for the PLC1-M7000, as
|
KM-ASSYH2-05
| 17
|
M7016
|
If the front section PLC1-M7016-EMO&&DOOR is opened, please check the safety door or emergency stop X17
|
Abnormal personnel operation
|
The solution for this error is to check the safety door or emergency stop X17 when the front section PLC1-M7016-EMO&&DOOR is opened.
|
KM-ASSYH2-05
| 18
|
M7017
|
Front stage PLC1-M7017-Equipment model setting is abnormal, please set the model
|
Abnormal personnel operation
|
The solution for the abnormal Front stage PLC1-M7017 equipment model setting is to set a new, valid model in the PLC. This can usually be done through the PLC's programming software or by physically reset
|
KM-ASSYH2-05
| 19
|
M7018
|
Front stage PLC1-M7018-Please press the reset button before starting the automatic process
|
Abnormal personnel operation
|
The solution for the Front stage PLC1-M7018 error described as "Please press the reset button before starting the automatic process" is as follows: Press the reset button before starting the automatic process. This process should restart and run
|
KM-ASSYH2-05
| 20
|
M7019
|
Previous PLC1-M7019-The equipment has not returned to the origin, please perform the equipment return to the origin first
|
Abnormal personnel operation
|
The solution to the error "Previous PLC1-M7019-The equipment has not returned to the origin, please perform the equipment return to the origin first" is to first perform the equipment return to the origin before proceeding with
|
KM-ASSYH2-05
| 21
|
M7020
|
Front section PLC1-M7020-There is material in the pressing area, please take it away first
|
Abnormal personnel operation
|
The solution for the "Pressing Area Full Error" in PLC1-M7020 is to remove any accumulated material from the pressing area before attempting to continue operation. This can be accomplished by physically removing the material or activating
|
KM-ASSYH2-05
| 22
|
M7021
|
Front stage PLC1-M7021-the Z-axis is not in the safe position during reset, please perform return to origin first
|
Abnormal personnel operation
|
The solution to the error "Front stage PLC1-M7021-the Z-axis is not in the safe position during reset" is to perform a return to origin first, which will ensure that the axis is in its safe
|
KM-ASSYH2-05
| 23
|
M7022
|
Previous section PLC1-M7022-timed out 10S while waiting for the scan code result
|
Visual abnormality
|
The solution for the error is to check the PLC's settings and ensure that the scan code result communication timeout is set correctly. If it is not working, you may need to update the PLC's firmware or contact technical support for
|
KM-ASSYH2-05
| 24
|
M7023
|
Front section PLC1-M7023-waiting for the camera to take pictures timed out 10S
|
Visual abnormality
|
The error "Front section PLC1-M7023-waiting for the camera to take pictures timed out 10S" can be resolved by checking the camera settings and ensuring that it is properly connected to the PLC
|
KM-ASSYH2-05
| 25
|
M7024
|
Front section PLC1-M7024-waiting for the next camera to take pictures timed out 10S
|
Visual abnormality
|
The solution for the error described as the front section PLC1-M7024 waiting for the next camera to take pictures timed out 10S could involve checking the camera configuration, ensuring proper camera communication, adjusting camera settings
|
KM-ASSYH2-05
| 26
|
M7025
|
Front-end PLC1-M7025-timeout 10S waiting for the host computer to reply to the assembly point
|
Machine communication abnormality
|
The solution for Front-end PLC1-M7025-timeout 10S waiting for the host computer to reply to the assembly point is to ensure that the host computer's firmware version is compatible with PLC1
|
KM-ASSYH2-05
| 28
|
M7027
|
Front stage PLC1-M7027-waiting for the host computer to reply LINK result timed out 10S
|
Machine communication abnormality
|
The solution for the described error is to increase the timeout value in the Link Communication Manager settings, such as by increasing the "Reply Timeout" setting to a value of 10 seconds or higher. It's also recommended to check the
|
Subsets and Splits
No community queries yet
The top public SQL queries from the community will appear here once available.